¡No lo dejes pasar! Libros de Penguin Random House y Grupo Planeta con 30% dcto  Ver más

menú

0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional
portada Optimum Cooling of Data Centers: Application of Risk Assessment and Mitigation Techniques (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
186
Encuadernación
Tapa Dura
Dimensiones
23.4 x 15.6 x 1.3 cm
Peso
0.46 kg.
ISBN13
9781461456018

Optimum Cooling of Data Centers: Application of Risk Assessment and Mitigation Techniques (en Inglés)

Diganta Das (Autor) · Jun Dai (Autor) · Michael M. Ohadi (Autor) · Springer · Tapa Dura

Optimum Cooling of Data Centers: Application of Risk Assessment and Mitigation Techniques (en Inglés) - Dai, Jun ; Ohadi, Michael M. ; Das, Diganta

Libro Nuevo

$ 638.855

$ 982.854

Ahorras: $ 343.999

35% descuento
  • Estado: Nuevo
  • Quedan 100+ unidades
Origen: Estados Unidos (Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el Lunes 12 de Agosto y el Lunes 26 de Agosto.
Lo recibirás en cualquier lugar de Colombia entre 1 y 5 días hábiles luego del envío.

Reseña del libro "Optimum Cooling of Data Centers: Application of Risk Assessment and Mitigation Techniques (en Inglés)"

This book describes the use of free air cooling to improve the efficiency of, and cooling of, equipment for use in telecom infrastructures. Discussed at length is the cooling of communication installation rooms such as data centers or base stations, and this is intended as a valuable tool for the people designing and manufacturing key parts of communication networks. This book provides an introduction to current cooling methods used for energy reduction, and also compares present cooling methods in use in the field. The qualification methods and standard reliability assessments are reviewed, and their inability to assess the risks of free air cooling is discussed. The method of identifying the risks associated with free air cooling on equipment performance and reliability is introduced. A novel method of assessment for free air cooling is also proposed that utilizes prognostics and health management (PHM).This book also: Describes how the implementation of free air cooling can save energy for cooling within the telecommunications infrastructure.Analyzes the potential risks and failures of mechanisms possible in the implementation of free air cooling, which benefits manufacturers and equipment designers.Presents prognostics-based assessments to identify and mitigate the risks of telecommunications equipment under free air cooling conditions, which can provide the early warning of equipment failures at operation stage without disturbing the data centers' service.Optimum Cooling for Data Centers is an ideal book for researchers and engineers interested in designing and manufacturing equipment for use in telecom infrastructures.

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Dura.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes